1.A comprehensive inspection of mechanical seals

as well as ancillary equipment and pipeline installation is complete, whether the technical requirements;


2.mechanical seal before the start of static pressure test

check the mechanical seal is leaking phenomenon.

If the leakage is more, should find out the reasons to try to eliminate. If it is still invalid, it should be disassembled and reinstalled. General static pressure test pressure with 2 to 3 kg / square centimeter;


3.press the pump to turn the car, check whether the light evenly. 